Details
BUY SII151BCT100 https://www.utsource.net/itm/p/11678236.html
| Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
|---|---|---|---|---|---|---|
| Supply Voltage | Vcc | Operating | 4.5 | - | 5.5 | V |
| Output Current | Iout | Continuous | - | 100 | - | mA |
| Quiescent Current | Iq | Vcc = 5V | - | 1.2 | - | mA |
| Dropout Voltage | Vdo | Iout = 100mA | - | 0.3 | - | V |
| Thermal Shutdown | TSD | Operation resumes | - | 160 | - | °C |
| Operating Temperature | Topr | Storage | -40 | - | 85 | °C |
Instructions for SII151BCT100
Power Supply Connection:
- Connect the supply voltage (Vcc) within the range of 4.5V to 5.5V to ensure stable operation.
Output Configuration:
- Ensure that the output current does not exceed 100mA continuously to prevent damage or overheating.
Quiescent Current Consideration:
- The quiescent current is typically 1.2mA at a supply voltage of 5V. Design your circuit considering this current consumption.
Dropout Voltage Awareness:
- The dropout voltage is typically 0.3V at an output current of 100mA. Ensure that your input voltage remains sufficiently higher than the desired output voltage by at least this amount.
Thermal Management:
- Monitor the operating temperature to avoid exceeding 160°C, which can trigger thermal shutdown. Allow adequate cooling if necessary.
Temperature Range Compliance:
- Operate the device within the temperature range of -40°C to 85°C for reliable performance.
Storage Conditions:
- When storing, keep the device in conditions that do not exceed the specified operating temperature range to maintain component integrity.