| Parameter | Symbol | Min | Typ | Max | Unit | Description |
|---|---|---|---|---|---|---|
| Supply Voltage | VDD | 2.5 | - | 5.5 | V | Operating supply voltage range |
| Output Current | IOUT | - | 100 | 300 | mA | Continuous output current |
| Quiescent Current | IQ | - | 10 | 20 | μA | Quiescent current at room temperature |
| Shutdown Current | ISD | - | 0.1 | 1 | μA | Shutdown mode current |
| Operating Temperature | TOPR | -40 | - | 125 | °C | Operating ambient temperature range |
| Thermal Shutdown | TSD | - | 160 | - | °C | Junction temperature thermal shutdown |
| Maximum Power Dissipation | PD | - | - | 800 | mW | Maximum power dissipation |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VDD) is within the specified range of 2.5V to 5.5V.
Output Current:
- The device can provide a continuous output current up to 300mA. For reliable operation, it is recommended to operate below the maximum limit.
Quiescent and Shutdown Current:
- The quiescent current is typically 10μA, which helps in minimizing power consumption during normal operation.
- When in shutdown mode, the current drops to as low as 0.1μA, aiding in battery-powered applications.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 125°C to ensure stable performance.
- Be aware that the device will automatically shut down if the junction temperature exceeds 160°C to prevent damage.
Power Dissipation:
- Keep the power dissipation below 800mW to avoid overheating and potential failure.
Handling and Installation:
- Follow standard handling procedures for electrostatic sensitive devices.
- Ensure proper heat sinking or cooling mechanisms are in place if operating near the maximum power dissipation limits.
Application Notes:
- Refer to the datasheet for detailed application circuits and layout guidelines to optimize performance.
View more about SI8050S on main site