Details
BUY 7MBP75RA060-05/75A600V https://www.utsource.net/itm/p/11881422.html
75A600V
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions/Notes |
|---|---|---|---|---|---|---|
| Forward Voltage Drop | V_F | - | 1.8 | - | V | @ IF = 75A, T_j = 25°C |
| Reverse Recovery Time | t_rr | - | 60 | - | ns | @ IF = 75A, IR = 10mA, T_j = 25°C |
| Reverse Recovery Charge | Q_rr | - | 140 | - | nC | @ IF = 75A, IR = 10mA, T_j = 25°C |
| Junction Capacitance | C_j | - | 30 | - | pF | @ VR = 0V, f = 1MHz |
| Maximum RMS Current | I_RM | - | - | 75 | A | |
| Peak Repetitive Reverse Voltage | V_RRMS | - | - | 600 | V | |
| Power Dissipation | P_TOT | - | - | 300 | W | @ T_c = 25°C |
| Operating Junction Temperature | T_op | -25 | - | 175 | °C |
Instructions for Use:
Mounting and Handling:
- Ensure proper handling to avoid damage to the device.
- Use appropriate mounting techniques to ensure good thermal contact.
Thermal Management:
- Ensure adequate heat sinking to maintain junction temperature within specified limits.
- Avoid exceeding the maximum power dissipation rating.
Electrical Connections:
- Connect the device according to the circuit diagram provided in the datasheet.
- Verify that all connections are secure and meet the current carrying capacity requirements.
Operational Limits:
- Do not exceed the maximum ratings listed in the table.
- Pay special attention to the peak repetitive reverse voltage and the operating junction temperature range.
Testing and Validation:
- Perform initial testing under controlled conditions to validate performance.
- Regularly monitor the device's parameters during operation to ensure reliability.
Storage and Packaging:
- Store in a dry, cool environment to prevent moisture damage.
- Follow ESD (Electrostatic Discharge) precautions when handling the device.
Note: For detailed specifications and additional information, refer to the manufacturer's datasheet or technical documentation.
(For reference only)View more about 7MBP75RA060-05/75A600V on main site