| Parameter | Symbol | Value | Unit | Notes |
|---|---|---|---|---|
| Input Voltage | VIN | 4.5 to 28 | V | Operating range |
| Output Voltage | VOUT | 0.8 to 5.5 | V | Adjustable |
| Output Current | IOUT | Up to 75 | A | Maximum continuous current |
| Switching Frequency | fSW | 600 | kHz | Fixed frequency |
| Efficiency | η | Up to 97% | % | Peak efficiency |
| Quiescent Current | IQ | 15 | μA | Shutdown mode |
| Protection Features | Overcurrent, | Includes overcurrent, overvoltage, | ||
| Overvoltage, | undervoltage, thermal shutdown | |||
| Undervoltage, | ||||
| Thermal Shutdown | ||||
| Package Type | QFN | 6x6 mm | ||
| Operating Temperature | Toper | -40 to +125 | °C | Junction temperature |
Instructions for FMG2G75US60
Input Voltage Configuration:
- Ensure the input voltage is within the specified range (4.5V to 28V).
Output Voltage Setting:
- Adjust the output voltage using external resistors according to the datasheet formula.
Output Current Limitation:
- Do not exceed the maximum output current of 75A continuously to avoid overheating or damage.
Switching Frequency:
- The device operates at a fixed switching frequency of 600kHz. No adjustment needed.
Efficiency Optimization:
- For optimal efficiency, operate within the recommended load and voltage conditions.
Protection Features:
- The device includes built-in protection against overcurrent, overvoltage, undervoltage, and thermal overload. Ensure proper heat dissipation for reliable operation.
Installation:
- Mount the device on a suitable PCB with adequate copper area for heat sinking. Follow the manufacturer's guidelines for layout recommendations.
Operating Temperature:
- Ensure the operating environment allows for junction temperatures between -40°C and +125°C. Monitor temperature under high load conditions.
View more about FMG2G75US60 on main site